Ancillary equipment to safeguard overall reliability
40 bar filters
Active carbon filter: highly efficient dust filter up to 0.1 micron
Oil vapor & odor removal filter: for filtration down to 0.005mg/m3/ oil carry-over
Both filters to be installed side-to-side
Medium and high pressure vessels for up to 45 bar
Volume 500-3000 liters (132/792 gallons)
Safe design for applications up to 45 bar (653 psi)
Hot dipped galvanized metallic tank
Cooling tower
Efficient cooling of closed loop water circuit
Water savings with drift eliminators
Maximum inlet water temperature 75°C (167°F)
Airblast cooling unit
Efficient cooling of the closed loop water circuit
Temperature approach: 5-15°C (41-59°F)
Maximum water temperature: 70°C (158°F)
Water pump skid
Optimization of the flow in the compressor closed loop circuit
Easy management: groups all the functions for operation of the cooling unit or tower
Energy recovery
Electrical input is not the only source of energy entering the system. The suction air for the compressor contains water vapor. The heat stored in the vapor is released through condensation in the inter- and aftercooler of the compressor. Typically the condensation heat, contained in the suction air, is equivalent to 5-20% of the electrical input energy.