Our overpressure range
ZL 1 & 2 (no starter version)
Right view
Left view
-
1
Reliable blower element
-
2
Cool canopy
-
3
Durable outlet connection
-
4
Immediate and understandable visual control of blower condition
-
5
Perfect protection of the unit
-
6
Maintenance free belt tensioning
-
7
Outdoor canopy
-
1
Reliable blower element
Tri-lobe blower element with traditionally selected strong bearing and gear set.
-
2
Cool canopy
Forced ventilation flow keeps the internal temperature of the canopy close to ambient temperature, contributing to the reliability of the unit. Option for outdoor version to use in conditions of -10 / + 55 °C.
-
3
Durable outlet connection
Integrated compensator with flange provides structural decoupling and installation alignment. Its stainless steel material brings a long lasting solution.
-
4
Immediate and understandable visual control of blower condition
The mechanical pressure and differential pressure gauges provide easy-to-read information about the outlet pressure and air filter condition.
-
5
Perfect protection of the unit
The safety and start-up function is integrated into our PVO valve, ensuring that pressure is always under control and that each blower start is smooth, contributing to trouble free operation.
-
6
Maintenance free belt tensioning
The automatic belt tensioning done by motor weight eliminates belt creeping and keeps the transmission efficiency high for the whole belt lifetime.
-
7
Outdoor canopy
The reliable design of ZL blowers makes it possible to install them where you need them, i.e. close to the technology, even outdoors. Efficient in ambient temperatures of -20 / + 50 °C.
ZL 3 & 4 (no starter version)
Right view
Left view
-
1
Reliable blower element
-
2
Cool canopy
-
3
Durable outlet connection
-
4
Immediate and understandable visual control of blower condition
-
5
Perfect protection of the unit
-
6
Maintenance free belt tensioning
-
7
Door handles to easily remove panels
-
8
Fork lift slots
-
1
Reliable blower element
Tri-lobe blower element with traditionally selected strong bearing and gear set.
-
2
Cool canopy
Forced ventilation flow keeps the internal temperature of the canopy close to ambient temperature, contributing to the reliability of the unit. Option for outdoor version to use in conditions of -10 / + 55 °C.
-
3
Durable outlet connection
Integrated compensator with flange provides structural decoupling and installation alignment. Its stainless steel material brings a long lasting solution.
-
4
Immediate and understandable visual control of blower condition
The mechanical pressure and differential pressure gauges provide easy-to-read information about the outlet pressure and air filter condition.
-
5
Perfect protection of the unit
The safety and start-up function is integrated into our PVO valve, ensuring that pressure is always under control and that each blower start is smooth, contributing to trouble free operation.
-
6
Maintenance free belt tensioning
The automatic belt tensioning done by motor weight eliminates belt creeping and keeps the transmission efficiency high for the whole belt lifetime.
-
7
Door handles to easily remove panels
The front and side panels each have two handles for easy access to the unit.
-
8
Fork lift slots
Fork lift slots are foreseen in the base frame of the unit to further simplify installation.
ZL 3 & 4 VSD (with starter VSD)
Right view
Left view
-
1
Reliable blower element
-
2
Cool canopy
-
3
Durable outlet connection
-
4
Immediate and understandable visual control of blower condition
-
5
Perfect protection of the unit
-
6
Maintenance free belt tensioning
-
7
Frequency converter
-
8
Door handles to easily remove panels
-
9
Fork lift slots
-
1
Reliable blower element
Tri-lobe blower element with traditionally selected strong bearing and gear set.
-
2
Cool canopy
Forced ventilation flow keeps the internal temperature of the canopy close to ambient temperature, contributing to the reliability of the unit. Option for outdoor version to use in conditions of -10 / + 55 °C.
-
3
Durable outlet connection
Integrated compensator with flange provides structural decoupling and installation alignment. Its stainless steel material brings a long lasting solution.
-
4
Immediate and understandable visual control of blower condition
The mechanical pressure and differential pressure gauges provide easy-to-read information about the outlet pressure and air filter condition.
-
5
Perfect protection of the unit
The safety and start-up function is integrated into our PVO valve, ensuring that pressure is always under control and that each blower start is smooth, contributing to trouble free operation.
-
6
Maintenance free belt tensioning
The automatic belt tensioning done by motor weight eliminates belt creeping and keeps the transmission efficiency high for the whole belt lifetime.
-
7
Frequency converter
Our Variable Speed Drive units have a Danfos frequency converter that ensures the motor speed is automatically adjusted to the flow demand.
-
8
Door handles to easily remove panels
The front and side panels each have two handles for easy access to the unit.
-
9
Fork lift slots
Fork lift slots are foreseen in the base frame of the unit to further simplify installation.