{"id":430892,"date":"2024-04-03T07:48:08","date_gmt":"2024-04-03T07:48:08","guid":{"rendered":"https:\/\/acoilfree-brochures.vintageproductions.eu\/brochure\/%tax%\/principe-de-fonctionnement-2\/"},"modified":"2024-10-24T09:56:55","modified_gmt":"2024-10-24T09:56:55","slug":"principe-de-fonctionnement-2","status":"publish","type":"brochure_page","link":"https:\/\/acoilfree-brochures.vintageproductions.eu\/fr\/brochure\/fdh-fr\/principe-de-fonctionnement-2\/","title":{"rendered":"Principe de fonctionnement"},"content":{"rendered":"<section class=\"wp-block-brochure-introduction-text \" style=\"margin-left:var(--vintage_margleft);margin-top:var(--vintage_margtop);margin-right:var(--vintage_margright);margin-bottom:var(--vintage_margbottom);padding-left:var(--vintage_paddleft);padding-top:var(--vintage_paddtop);padding-right:var(--vintage_paddright);padding-bottom:var(--vintage_paddbottom);\">\n    <div class=\"container large-pdf\">\n        <div class=\"grid\">\n                <div class=\"title-container\">\n                                            <h1 class=\"title h1 max-line\">\n                            <span class=\"title-text\">Principe de fonctionnement<\/span>\n                        <\/h1>\n                                        <\/div>\n                <div class=\"text\">\n                    <p><\/p>                <\/div>\n            <\/div>\n    <\/div>\n\t<\/section>\n<div class=\"custom-wp-columns is-layout-flex wp-container-core-columns-is-layout-1 custom-wp-columns-is-layout-flex\"><div class=\"container wp-block-columns\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><section class=\"wp-block-brochure-image-full  anim-block anim-block-bottom\" style=\"margin-left:var(--vintage_margleft);margin-top:var(--vintage_margtop);margin-right:var(--vintage_margright);margin-bottom:var(--vintage_margbottom);padding-left:var(--vintage_paddleft);padding-top:var(--vintage_paddtop);padding-right:var(--vintage_paddright);padding-bottom:var(--vintage_paddbottom);\">\n\t        <div class=\"container\">\n\t            <img loading=\"lazy\" decoding=\"async\" width=\"553\" height=\"247\" src=\"https:\/\/acoilfree-brochures.vintageproductions.eu\/wp-content\/uploads\/sites\/1\/2024\/04\/picture1.png\" class=\"img\" alt=\"\" data-id=\"298109\">                    <\/div>\n\t\t\n<\/section>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><section class=\"wp-block-brochure-legend-block halign-1 vpos-2 size-1 design-2\">\n\t<div class=\"container\">\n\t\t<div class=\"grid\">\n\t\t\t<div class=\"legend-block\">\n\t\t\t\t<p>1. Refrigerant compressor<\/p><p>2. Condensor<\/p><p>3. Motor fan<\/p><p>4. Air-to-refrigerant heat exchanger\/evaporator<\/p><p>5. Water-air-separator<\/p><p>6. Condensate drain<\/p><p>7. Capillary tube<\/p><p>8. Filter<\/p><p>9. Liquid separator<\/p><p>10. Air-to-air heat exchanger<\/p><p>11. Dew point indicator<\/p><p>12. High pressure switch<\/p><p>13. Hot gas bypass valve<\/p>\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n<\/section>\n<\/div>\n<\/div><\/div>\n<div class=\"custom-wp-columns is-layout-flex wp-container-core-columns-is-layout-2 custom-wp-columns-is-layout-flex\"><div class=\"container wp-block-columns\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><section class=\"wp-block-brochure-text-block \" style=\"margin-left:var(--vintage_margleft);margin-top:var(--vintage_margtop);margin-right:var(--vintage_margright);margin-bottom:var(--vintage_margbottom);padding-left:var(--vintage_paddleft);padding-top:var(--vintage_paddtop);padding-right:var(--vintage_paddright);padding-bottom:var(--vintage_paddbottom);\">\n\t<div class=\"container\">\n        <div class=\"grid\">\n            <div class=\"text anim-block anim-block-bottom\">\n                <p><span class=\"custom-text-large\"><span class=\"custom-text-highlight\">Circuit d&rsquo;air<\/span><\/span><\/p><p>L&rsquo;air comprim&eacute; qui doit s&eacute;cher p&eacute;n&egrave;tre dans la section d&rsquo;&eacute;change de chaleur A-A (10), puis est refroidi par la sortie, &agrave; une temp&eacute;rature inf&eacute;rieure et &agrave; l&rsquo;air sec. En raison de la baisse de la temp&eacute;rature, la vapeur d&rsquo;eau contenue dans l&rsquo;air d&rsquo;admission commence &agrave; se condenser. L&rsquo;air entre ensuite dans l&rsquo;&eacute;vaporateur (4) et est refroidi davantage jusqu&rsquo;&agrave; atteindre la temp&eacute;rature d&rsquo;&eacute;vaporation du r&eacute;frig&eacute;rant. Une plus grande quantit&eacute; d&rsquo;eau liquide se condense. L&rsquo;air froid contenant des gouttelettes d&rsquo;eau liquide traverse alors la section WSD (5) o&ugrave; l&rsquo;eau liquide est s&eacute;par&eacute;e de l&rsquo;air. L&rsquo;eau liquide est &eacute;vacu&eacute;e par la vanne de vidange (6). Ensuite, l&rsquo;air froid et s&eacute;ch&eacute; retourne &agrave; la section d&rsquo;&eacute;change de chaleur A-A (10) o&ugrave; il est chauff&eacute; par l&rsquo;air d&rsquo;entr&eacute;e chaud et humide, puis sort par la sortie d&rsquo;air de l&rsquo;&eacute;changeur de chaleur. <\/p>            <\/div>\n        <\/div>\n\t<\/div>\n<\/section>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><section class=\"wp-block-brochure-text-block \" style=\"margin-left:var(--vintage_margleft);margin-top:var(--vintage_margtop);margin-right:var(--vintage_margright);margin-bottom:var(--vintage_margbottom);padding-left:var(--vintage_paddleft);padding-top:var(--vintage_paddtop);padding-right:var(--vintage_paddright);padding-bottom:var(--vintage_paddbottom);\">\n\t<div class=\"container\">\n        <div class=\"grid\">\n            <div class=\"text anim-block anim-block-bottom\">\n                <p><span class=\"custom-text-highlight\"><span class=\"custom-text-large\">Circuit du fluide r&eacute;frig&eacute;rant<\/span><\/span><\/p><p>Le compresseur de r&eacute;frig&eacute;rant&nbsp;(1) conduit le gaz r&eacute;frig&eacute;rant &agrave; haute temp&eacute;rature et &agrave; haute pression &agrave; travers le condenseur refroidi par eau\/air&nbsp;(2), o&ugrave; le gaz r&eacute;frig&eacute;rant se condense en r&eacute;frig&eacute;rant liquide. Le r&eacute;frig&eacute;rant liquide passe ensuite &agrave; travers le filtre du s&eacute;cheur (8) (pour &eacute;viter l&rsquo;humidit&eacute; et les particules), puis vers l&rsquo;&eacute;l&eacute;ment d&rsquo;expansion (d&eacute;tendeur ou capillaire) (7). Apr&egrave;s avoir travers&eacute; l&rsquo;&eacute;l&eacute;ment d&rsquo;expansion (7), le r&eacute;frig&eacute;rant passe &agrave; une temp&eacute;rature et une pression beaucoup plus basses. Ce r&eacute;frig&eacute;rant p&eacute;n&egrave;tre ensuite dans l&rsquo;&eacute;vaporateur (4) et absorbe la chaleur de l&rsquo;air comprim&eacute; d&rsquo;admission chaud pour s&rsquo;&eacute;vaporer. Apr&egrave;s &eacute;vaporation, le r&eacute;frig&eacute;rant gazeux (ou le m&eacute;lange gaz\/liquide) retourne &agrave; l&rsquo;aspiration du compresseur de r&eacute;frig&eacute;rant (1) apr&egrave;s le s&eacute;parateur gaz\/liquide (9) (pour &eacute;viter un &eacute;ventuel choc de liquide). L&rsquo;interrupteur de protection haute pression (12) est utilis&eacute; pour &eacute;viter que la pression du r&eacute;frig&eacute;rant ne soit trop &eacute;lev&eacute;e. Lorsque la charge est faible ou nulle, la vanne de d&eacute;rivation de gaz chaud (HGB) (13) permet de d&eacute;river le r&eacute;frig&eacute;rant de gaz chaud de la sortie du compresseur pour &eacute;viter une &eacute;ventuelle d&eacute;faillance due au gel (bloc de glace). <\/p>            <\/div>\n        <\/div>\n\t<\/div>\n<\/section>\n<\/div>\n<\/div><\/div>\n<section class=\"wp-block-brochure-text-block \" style=\"margin-left:var(--vintage_margleft);margin-top:var(--vintage_margtop);margin-right:var(--vintage_margright);margin-bottom:var(--vintage_margbottom);padding-left:var(--vintage_paddleft);padding-top:var(--vintage_paddtop);padding-right:var(--vintage_paddright);padding-bottom:var(--vintage_paddbottom);\">\n\t<div class=\"container\">\n        <div class=\"grid\">\n            <div class=\"text anim-block anim-block-bottom\">\n                <p><span class=\"custom-text-highlight\"><span class=\"custom-text-large\">Syst\u00e8me de r\u00e9gulation automatique<\/span><\/span><\/p><p>La pression du condenseur doit \u00eatre maintenue aussi constante que possible pour garantir un fonctionnement stable. L&rsquo;interrupteur de commande du ventilateur arr\u00eate et d\u00e9marre le ventilateur (3). Si, lorsque la charge est partielle ou nulle, la pression de l&rsquo;\u00e9vaporateur chute en dessous d&rsquo;un certain niveau, la vanne de d\u00e9rivation de gaz chaud (9) s&rsquo;ouvre et du gaz chaud sous haute pression est envoy\u00e9 dans le circuit de l&rsquo;\u00e9vaporateur pour emp\u00eacher la pression de l&rsquo;\u00e9vaporateur de chuter davantage. <\/p>            <\/div>\n        <\/div>\n\t<\/div>\n<\/section>\n","protected":false},"template":"","brochures":[617],"_links":{"self":[{"href":"https:\/\/acoilfree-brochures.vintageproductions.eu\/fr\/wp-json\/wp\/v2\/brochure_page\/430892"}],"collection":[{"href":"https:\/\/acoilfree-brochures.vintageproductions.eu\/fr\/wp-json\/wp\/v2\/brochure_page"}],"about":[{"href":"https:\/\/acoilfree-brochures.vintageproductions.eu\/fr\/wp-json\/wp\/v2\/types\/brochure_page"}],"version-history":[{"count":2,"href":"https:\/\/acoilfree-brochures.vintageproductions.eu\/fr\/wp-json\/wp\/v2\/brochure_page\/430892\/revisions"}],"predecessor-version":[{"id":433658,"href":"https:\/\/acoilfree-brochures.vintageproductions.eu\/fr\/wp-json\/wp\/v2\/brochure_page\/430892\/revisions\/433658"}],"wp:attachment":[{"href":"https:\/\/acoilfree-brochures.vintageproductions.eu\/fr\/wp-json\/wp\/v2\/media?parent=430892"}],"wp:term":[{"taxonomy":"brochures","embeddable":true,"href":"https:\/\/acoilfree-brochures.vintageproductions.eu\/fr\/wp-json\/wp\/v2\/brochures?post=430892"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}