TDV 01-06 FE (EC ファン) 諸元表(メートル法単位)

ドライクーラ

Technical specifications TDV 01 A TDV 02 A TDV 03 A TDV 04 A TDV 05 A TDV 06 A
Cooling capacity (1) [kW] 67 133 228 313 378 478
Nominal water flow (1) [m3/h] 6 12 20.8 28.6 34 42.6
Total air flow [m3/h] 27,000 54,000 81,000 108,000 135,000 162,000

蒸発冷却式ドライクーラ

Technical specifications TDV 01 AD TDV 02 AD TDV 03 AD TDV 04 AD TDV 05 AD TDV 06 AD
Cooling capacity (1) [kW] 118 232 384 560 643 775
Nominal water flow (1) [m3/h] 11 21 34 46.3 57 63.5
Total air flow [m3/h] 24,000 48,000 72,000 96,000 120,000 144,000
Dimensions
L(3) [mm] 1975 3125 4283 5433 6583 7855
W [mm] 2115
H [mm] 2174
Total installed power (2) [kW] 3,2 5,6 8,1 10,5 13 15,5
Maximum absorbed current (2) [A] 4,3 8,1 11,9 15,7 19,5 23,3
Axial Fans Qty./Diam. [No./mm] 1/900 2/900 3/900 4/900 5/900 6/900
Water content [l] 64 94 209 258 316 359
Hydraulic connection – in/out 3″ 4″
Fan control EC motors on fans
Controller ElektronikonTM MK5S + SMARTLINK
Power supply [V/Ph/Hz] 400/3+PE/50 or 460/3+PE/60
Auxiliary voltage 24Vdc
Electrical approval IEC/cULus
Pressure vessel approval PED 2014/68/UE

(1) 基準状態:周囲温度 35°C、相対湿度 40%;冷却水温度 入口 50°C / 出口 40°C、ポンプあり / なし;グリコール濃度 25%;設置標高 0 m
(2) 記載値は「ポンプなし」仕様の場合です。
(3) 記載寸法はマニホールドなし仕様の値です。