General |
IP grade |
IP54 |
IP54 |
IP54 |
IP54 |
IP54 |
IP54 |
|
Cooler Version |
Dry cooler |
V |
V |
V |
V |
V |
V |
|
Cooler Version |
Adiabatic cooler |
V |
V |
V |
V |
V |
V |
|
Air filter screens |
Aluminium Air filter |
opt |
opt |
opt |
opt |
opt |
opt |
|
Installation |
Lifting with ropes + spreader beam |
⚫ |
⚫ |
⚫ |
⚫ |
⚫ |
⚫ |
|
Electrical |
400V/3ph 50Hz IEC |
V |
V |
V |
V |
V |
V |
|
460V/3ph 60Hz UL 508A |
V |
V |
V |
V |
V |
V |
|
Energy meter |
opt |
opt |
opt |
opt |
opt |
opt |
|
Control |
Controller type |
Electronikon Mk5S |
Electronikon Mk5S |
Electronikon Mk5S |
Electronikon Mk5S |
Electronikon Mk5S |
Electronikon Mk5S |
|
4,3″ touchscreen |
⚫ |
|
Text on display in local language (english, italiano, deutsch, slovensko, espanol, francais) |
⚫ |
|
Day and week scheduler |
⚫ |
|
Service timer |
⚫ |
|
Dynamic set-point |
⚫ |
|
Safety |
Thermal-magnetic circuit breakers protection on fans and pumps |
⚫ |
|
Flow switch |
opt |
|
Winter protection: auto-ON of the pump with low ambient temperature (software function) |
⚫ |
|
Remote temperature sensor |
opt |
|
System integration |
Remote ON-OFF |
⚫ |
|
Single free contact for warning & shut down alarm |
⚫ |
|
Remote setpoint + Temperature transmission (4..20mA) |
opt |
|
Modbus RTU – RS485 |
accessory |
|
CANbus |
accessory |
|
Profibus |
accessory |
|
Profinet |
accessory |
|
TCP |
accessory |
|
Ehernet IP |
accessory |
|
Remote control panel |
accessory |
|
Connectivity |
Smartlink connectivity incl modem (4G), incl ‘service’ license |
⚫ |
|
Smartlink UPTIME license |
opt |
|
Hydronics |
No Pump |
⚫ |
|
Circulation Pump stainless steel (cooling water manifold included) |
V |
|
Standby Circulation Pump stainless steel (cooling water manifold included) |
V |
|
Cooling water manifold |
opt |
|
Manual filling system and drain |
⚫ |
|
Automatic filling with: city water line filter, pressure reducer |
opt |
|
Expansion vessels 24l |
opt |
|
Expansion vessels 80l |
opt |
|
Water pressure gauge (only if pump is included) |
⚫ |
|
Grooved water connections: 3″ |
⚫ |
– |
|
Grooved water connections: 4″ |
– |
⚫ |
|
Flanged connection: UNI flanges |
opt |
|
Flanged connection: ANSI flanges |
opt |
|
Counterflanges |
opt |
|
External manual by-pass (only if manifold is included) |
⚫ |
|
Adiabatic system |
Descaling Filter |
opt |
|
Fan |
AC fans |
⚫ |
|
Variable speed control for fans – phase cut controller |
V |
|
Variable speed control for fans – VFD (mounted inside cabinet) |
V |
– |
|
Variable speed control for fans – VFD (mounted outside cabinet with metal protection) |
– |
V |
|
Heat exchanger |
Aluminum fins/copper tube coil |
⚫ |
|
Packaging |
Plastic wrap protection |
⚫ |
|
Wooden base |
opt |
|
Wooden case (close box) |
opt |
|
⚫ |
Standard |
|
V |
Version: select the correct equipment material number |
|
opt |
Optional accessory |
|
– |
Not available |