Se hele produktutvalget vårt
| Features | TDV 01 | TDV 02 | TDV 03 | TDV 04 | TDV 05 | TDV 06 |
| GENERAL | GENERAL | |||||
| IP grade | IP54 | IP54 | IP54 | IP54 | IP54 | IP54 |
| Aluminium air filter | opt | opt | opt | opt | opt | opt |
| Lifting with ropes + spreader beam | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| COOLER VERSION | ||||||
| Dry cooler | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Adiabatic cooler | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| ELECTRICAL | ||||||
| 400V/3ph 50 Hz IEC | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| 460V/3ph 60 Hz UL 508A | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Energy meter | opt | opt | opt | opt | opt | opt |
| CONTROL | ||||||
| Controller type | Elektronikon Mk5S | Elektronikon Mk5S | Elektronikon Mk5S | Elektronikon Mk5S | Elektronikon Mk5S | Elektronikon Mk5S |
| 4,3″ touchscreen | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
|
Text on display in local language (english, italiano, deutsch, slovensko, espanol, francais) |
⚫ | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Day and week scheduler | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Service timer | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Dynamic set-point | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| SAFETY | ||||||
| Thermal-magnetic circuit breakers protection on fans and pumps | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Flow switch | opt | opt | opt | opt | opt | opt |
| Winter protection: auto-ON of the pump with low ambient temperature (software function) | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Remote temperature sensor | opt | opt | opt | opt | opt | opt |
| SYSTEM INTEGRATION | ||||||
| Remote ON-OFF | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Single free contact for warning & shut down alarm | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Remote setpoint + Temperature transmission (4.20 mA) | opt | opt | opt | opt | opt | opt |
| Modbus RTU – RS485 | accessory | accessory | accessory | accessory | accessory | accessory |
| CANbus | accessory | accessory | accessory | accessory | accessory | accessory |
| Profibus | accessory | accessory | accessory | accessory | accessory | accessory |
| Profinet | accessory | accessory | accessory | accessory | accessory | accessory |
| TCP | accessory | accessory | accessory | accessory | accessory | accessory |
| Ethernet IP | accessory | accessory | accessory | accessory | accessory | accessory |
| Remote control panel | accessory | accessory | accessory | accessory | accessory | accessory |
| CONNECTIVITY | ||||||
| Smartlink connectivity incl modem (4G), incl ‘service’ license | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Smartlink UPTIME license | opt | opt | opt | opt | opt | opt |
| HYDRONICS | ||||||
| No pump | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Circulation pump stainless steel (cooling water manifold included) | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Standby circulation pump stainless steel (cooling water manifold included) | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Cooling water manifold | opt | opt | opt | opt | opt | opt |
| Manual filling system and drain | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Automatic filling with: city water line filter, pressure reducer | opt | opt | opt | opt | opt | opt |
| Expansion vessels 24L | opt | opt | opt | opt | opt | opt |
| Expansion vessels 80L | opt | opt | opt | opt | opt | opt |
| Water pressure gauge (only if pump is included) | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Grooved water connections: 3″ | ⚫ | ⚫ | – | – | – | – |
| Grooved water connections: 4″ | – | – | ⚫ | ⚫ | ⚫ | ⚫ |
| Flanged connection: UNI flanges | opt | opt | opt | opt | opt | opt |
| Flanged connection: ANSI flanges | opt | opt | opt | opt | opt | opt |
| Counterflanges | – | – | – | – | – | – |
| External manual by-pass (only if manifold is included) | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| ADIABATIC SYSTEM | ||||||
| Descaling filter | opt | opt | opt | opt | opt | opt |
| FAN | ||||||
| AC fans | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Variable speed control for fans – phase cut controller | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Variable speed control for fans – VFD (mounted inside cabinet) | ✓ | ✓ | ✓ | – | – | – |
| Variable speed control for fans – VFD (mounted outside cabinet with metal protection) | – | – | – | ✓ | ✓ | ✓ |
| EC Brushless fans | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| HEAT EXCHANGER | ||||||
| Aluminum fins/copper tube coil | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| PACKAGING | ||||||
| Plastic wrap protection | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Wooden base | opt | opt | opt | opt | opt | opt |
| Wooden case (close box) | opt | opt | opt | opt | opt | opt |
| FEATURES | TDV 01-02 | TDV 03 | TDV 04-06 | TDV 22-24 | TDV 25-29 |
| General | IP54 | ||||
| Cooler version | Cooler version | Cooler version | Cooler version | Cooler version | Cooler version |
| Dry cooler | V | V | V | V | V |
| Adiabatic cooler | V | V | V | V | V |
| Air filter screens | |||||
| Aluminium Air filter | opt | opt | opt | opt | opt |
| Installation | Installation | Installation | Installation | Installation | Installation |
| Lifting with ropes + spreader beam | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Electrical | Electrical | Electrical | Electrical | Electrical | Electrical |
| 400V/3ph 50Hz IEC | V | V | V | – | – |
| 460V/3ph 60Hz UL 508A | V | V | V | – | – |
| 380V-460V/3Ph/50-60 Hz IEC | – | – | – | V | V |
| 380V-460V/3Ph/50-60 Hz UL 508A | – | – | – | V | V |
| Energy meter | opt | opt | opt | opt | opt |
| Control | Control | Control | Control | Control | Control |
| Controller type | Electronikon Mk5S | Electronikon Mk5S | Electronikon Mk5S | Electronikon Mk5S | Electronikon Mk5S |
| 4,3″ touchscreen | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Text on display in local language (english, italiano, deutsch, slovensko, espanol, francais) | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Day and week scheduler | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Service timer | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Dynamic set-point | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Safety | Safety | Safety | Safety | Safety | Safety |
| Thermal-magnetic circuit breakers protection on fans and pumps (pumps only for TDV 0) | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Individual fan safety switches | – | – | – | opt | opt |
| Flow switch | opt | opt | opt | opt | opt |
| Winter protection: auto-ON of the pump with low ambient temperature (software function) | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Remote temperature sensor | opt | opt | opt | opt | opt |
| System integration | System integration | System integration | System integration | System integration | System integration |
| Remote ON-OFF | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Single free contact for warning & shut down alarm | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Remote setpoint + Temperature transmission (4..20mA) | opt | opt | opt | opt | opt |
| Modbus RTU – RS485 | accessory | accessory | accessory | accessory | accessory |
| CANbus | accessory | accessory | accessory | accessory | accessory |
| Profibus | accessory | accessory | accessory | accessory | accessory |
| Profinet | accessory | accessory | accessory | accessory | accessory |
| TCP | accessory | accessory | accessory | accessory | accessory |
| Ehernet IP | accessory | accessory | accessory | accessory | accessory |
| Remote control panel | accessory | accessory | accessory | accessory | accessory |
| Connectivity | Connectivity | Connectivity | Connectivity | Connectivity | Connectivity |
| Smartlink connectivity incl modem (4G), incl ‘service’ license | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Smartlink UPTIME license | opt | opt | opt | opt | opt |
| Hydronics | Hydronics | Hydronics | Hydronics | Hydronics | Hydronics |
| No Pump | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Circulation Pump stainless steel (cooling water manifold included) | V | V | V | – | – |
| Standby Circulation Pump stainless steel (cooling water manifold included) | V | V | V | – | – |
| Cooling water manifold | opt | opt | opt | ||
| Manual filling system and drain | ⚫ | ⚫ | ⚫ | – | – |
| Automatic filling with: city water line filter, pressure reducer | opt | opt | opt | – | – |
| Expansion vessels 24l | opt | opt | opt | – | – |
| Expansion vessels 80l | opt | opt | opt | ||
| Water pressure gauge (only if pump is included) | ⚫ | ⚫ | ⚫ | – | – |
| Grooved water connections: 3″ | ⚫ | – | – | ⚫ | – |
| Grooved water connections: 4″ | – | ⚫ | ⚫ | – | ⚫ |
| Flanged connection: UNI flanges | opt | opt | opt | opt | opt |
| Flanged connection: ANSI flanges | opt | opt | opt | opt | opt |
| External manual by-pass (only if manifold is included) | ⚫ | ⚫ | ⚫ | – | – |
| Adiabatic system | Adiabatic system | Adiabatic system | Adiabatic system | Adiabatic system | Adiabatic system |
| Descaling Filter | opt | opt | opt | opt | opt |
| Fan | Fan | Fan | Fan | Fan | Fan |
| AC fans | ⚫ | ⚫ | ⚫ | – | – |
| Variable speed control for fans – phase cut controller | V | V | V | – | – |
| Variable speed control for fans – VFD (mounted inside cabinet) | V | V | – | – | – |
| Variable speed control for fans – VFD (mounted outside cabinet with metal protection) | – | – | V | – | – |
| EC Brushless fans | V | V | V | ⚫ | ⚫ |
| Heat exchanger | Heat exchanger | Heat exchanger | Heat exchanger | Heat exchanger | Heat exchanger |
| Aluminum fins/copper tube coil | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Corrosion protection (Blygold coating) | opt | opt | opt | – | – |
| Packaging | Packaging | Packaging | Packaging | Packaging | Packaging |
| Plastic wrap protection | ⚫ | ⚫ | ⚫ | ⚫ | ⚫ |
| Wooden base | opt | opt | opt | – | – |
| Wooden case (close box) | opt | opt | opt | opt | opt |
⚫ = Standard
✓ = Versjon: velg riktig utstyrsmaterialenummer
opt = Valgfritt tilbehør
– = Ikke tilgjengelig