Dane techniczne
Dane techniczne ZR 200–355 VSD⁺ FF (iMDG)
Model | Working pressure | Free Air Delivery (1) | Installed motor power | Noise level (2) | Weight | ||
bar(e) | l/s | m³/min | kW | dB(A) | kg | ||
ZR 200 VSD⁺ 10.4 | Minimum | 6 | 209 – 689 | 12.5 – 41.3 | 200 | 72 |
Pack: 4979 iMDG dryer: 2530 |
ZR 200 VSD⁺ 10.4 | Effective | 7 | 209 – 652 | 12.5 – 39.1 | 200 | 72 |
Pack: 4979 iMDG dryer: 2530 |
ZR 200 VSD⁺ 10.4 | Maximum | 10.4 | 208 – 524 | 12.5 – 31.4 | 200 | 72 |
Pack: 4979 iMDG dryer: 2530 |
ZR 250 VSD⁺ 10.4 | Minimum | 6 | 209 – 834 | 12.5 – 50.0 | 250 | 73 |
Pack: 4979 iMDG dryer: 2530 |
ZR 250 VSD⁺ 10.4 | Effective | 7 | 209 – 796 | 12.5 – 47.8 | 250 | 73 |
Pack: 4979 iMDG dryer: 2530 |
ZR 250 VSD⁺ 10.4 | Maximum | 10.4 | 208 – 664 | 12.5 – 39.8 | 250 | 73 |
Pack: 4979 iMDG dryer: 2530 |
ZR 315 VSD⁺ 10.4 | Minimum | 6 | 209 – 960 | 12.5 – 57.6 | 315 | 73 |
Pack: 4979 iMDG dryer: 2530 |
ZR 315 VSD⁺ 10.4 | Effective | 7 | 209 – 960 | 12.5 – 57.6 | 315 | 73 |
Pack: 4979 iMDG dryer: 2530 |
ZR 315 VSD⁺ 10.4 | Maximum | 10.4 | 208 – 830 | 12.5 – 49.8 | 315 | 73 |
Pack: 4979 iMDG dryer: 2530 |
ZR 355 VSD⁺ 8.6 | Minimum | 6 | 208 – 1064 | 12.5 – 63.8 | 355 | 73 |
Pack: 4979 iMDG dryer: 2530 |
ZR 355 VSD⁺ 8.6 | Effective | 7 | 208 – 1064 | 12.5 – 63.8 | 355 | 73 |
Pack: 4979 iMDG dryer: 2530 |
ZR 355 VSD⁺ 8.6 | Maximum | 8.6 | 209 – 998 | 12.5 – 59.9 | 355 | 73 |
Pack: 4979 iMDG dryer: 2530 |
ZR 355 VSD⁺ 10.4 | Minimum | 6 | 209 – 998 | 12.5 – 59.9 | 355 | 73 |
Pack: 4979 iMDG dryer: 2530 |
ZR 355 VSD⁺ 10.4 | Effective | 7 | 209 – 998 | 12.5 – 59.9 | 355 | 73 |
Pack: 4979 iMDG dryer: 2530 |
ZR 355 VSD⁺ 10.4 | Maximum | 10.4 | 208 – 924 | 12.5 – 55.4 | 355 | 73 |
Pack: 4979 iMDG dryer: 2530 |
Wymiary ZR 200–355 VSD⁺ FF (iMDG)
Model | Length | Width | Height |
Model | mm | ||
ZR 200-355 VSD⁺ FF (iMDG) | 5651 | 1927 | 2150 |
ImperialMetric
Units
Working pressure bar(e)
6
7
10.4
8.6
Installed motor power kW
200
250
315
355
(1) Osiągi urządzenia mierzone wg normy ISO 1217, załącznik E, wydanie 4 (2009).
Warunki odniesienia:
– Wilgotność względna: 0%
– Ciśnienie bezwzględne na wlocie: 1 bar (14,5 psi)
– Temperatura powietrza na wlocie: 20°C (68°F)
Wydatek sprężarki (FAD) jest mierzony przy efektywnym ciśnieniu roboczym.
(2) Średni poziom ciśnienia akustycznego emisji na stanowisku pracy ważonego filtrem A (LpWSAd). Zmierzony zgodnie z normą ISO 2151:2008 metodą ISO 9614-2 (metoda pomiaru intensywności dźwięku). Przyjęty współczynnik poprawki (+/-3 dB(A)) jest całkowitą wartością niepewności (KpAd) zgodną z przepisami testowania.