Model | Working pressure | Free Air Delivery (1) | Installed motor power | Noise level (2) | Weight | ||
bar(e) | l/s | m³/min | kW | dB(A) | kg | ||
ZR 200 VSD⁺ 10.4 | Minimum | 6 | 209 – 689 | 12.5 – 41.3 | 200 | 72 |
Pack: 4979 iMDG dryer: 2530 |
ZR 200 VSD⁺ 10.4 | Effective | 7 | 209 – 652 | 12.5 – 39.1 | 200 | 72 |
Pack: 4979 iMDG dryer: 2530 |
ZR 200 VSD⁺ 10.4 | Maximum | 10.4 | 208 – 524 | 12.5 – 31.4 | 200 | 72 |
Pack: 4979 iMDG dryer: 2530 |
ZR 250 VSD⁺ 10.4 | Minimum | 6 | 209 – 834 | 12.5 – 50.0 | 250 | 73 |
Pack: 4979 iMDG dryer: 2530 |
ZR 250 VSD⁺ 10.4 | Effective | 7 | 209 – 796 | 12.5 – 47.8 | 250 | 73 |
Pack: 4979 iMDG dryer: 2530 |
ZR 250 VSD⁺ 10.4 | Maximum | 10.4 | 208 – 664 | 12.5 – 39.8 | 250 | 73 |
Pack: 4979 iMDG dryer: 2530 |
ZR 315 VSD⁺ 10.4 | Minimum | 6 | 209 – 960 | 12.5 – 57.6 | 315 | 73 |
Pack: 4979 iMDG dryer: 2530 |
ZR 315 VSD⁺ 10.4 | Effective | 7 | 209 – 960 | 12.5 – 57.6 | 315 | 73 |
Pack: 4979 iMDG dryer: 2530 |
ZR 315 VSD⁺ 10.4 | Maximum | 10.4 | 208 – 830 | 12.5 – 49.8 | 315 | 73 |
Pack: 4979 iMDG dryer: 2530 |
ZR 355 VSD⁺ 8.6 | Minimum | 6 | 208 – 1064 | 12.5 – 63.8 | 355 | 73 |
Pack: 4979 iMDG dryer: 2530 |
ZR 355 VSD⁺ 8.6 | Effective | 7 | 208 – 1064 | 12.5 – 63.8 | 355 | 73 |
Pack: 4979 iMDG dryer: 2530 |
ZR 355 VSD⁺ 8.6 | Maximum | 8.6 | 209 – 998 | 12.5 – 59.9 | 355 | 73 |
Pack: 4979 iMDG dryer: 2530 |
ZR 355 VSD⁺ 10.4 | Minimum | 6 | 209 – 998 | 12.5 – 59.9 | 355 | 73 |
Pack: 4979 iMDG dryer: 2530 |
ZR 355 VSD⁺ 10.4 | Effective | 7 | 209 – 998 | 12.5 – 59.9 | 355 | 73 |
Pack: 4979 iMDG dryer: 2530 |
ZR 355 VSD⁺ 10.4 | Maximum | 10.4 | 208 – 924 | 12.5 – 55.4 | 355 | 73 |
Pack: 4979 iMDG dryer: 2530 |
Rozmery ZR 200 – 355 VSD⁺ FF (iMDG)
Model | Length | Width | Height |
Model | mm | ||
ZR 200-355 VSD⁺ FF (iMDG) | 5651 | 1927 | 2150 |
ImperialMetric
Units
Working pressure bar(e)
6
7
10.4
8.6
Installed motor power kW
200
250
315
355
(1) Výkon zariadenia meraný podľa normy ISO 1217, príloha E, vydanie 4 (2009).
Referenčné podmienky:
– Relatívna vlhkosť 0 %
– Absolútny tlak na vstupe 1 bar (14,5 psi)
– Teplota vzduchu prívodu 20 °C/68 °F
Dodávka voľného vzduchu (FAD) sa meria pri efektívnom prevádzkovom tlaku.
(2) Hladina vysielaného akustického tlaku na pracovisku hodnotená váhovým filtrom A (LpWSAd). Namerané podľa normy ISO 2151: 2008 s využitím normy ISO 9614-2 (metóda snímania intenzity zvuku). Pomocným korekčným koeficientom (+/– 3 dB(A)) je celková hodnota nepresnosti (KpAd) v súlade predpismi vykonávania testovania.