Technical Specifications iMD ZT
Specifications ZT 160-315 (VSD) iMD
| Model | Working pressure | Free Air Delivery | Installed Power | Noise level | Weight | |||||
| bar(g) | psi(g) | l/s | m³/min | cfm | kW | hp | db(A) | kg /lbs | ||
| ZT 200 VSD- 8.6 | Minimum | 6 | 87 | 194-636 | 11.6-38.2 | 411-1348 | 200 | 268 | 75 | 7159 / 15783 |
| Effective | 7 | 102 | 193-602 | 11.6-36.1 | 410-1275 | |||||
| Maximum | 8.6 | 125 | 192-540 | 11.5-32.4 | 407-1145 | |||||
| ZT 250 VSD – 8.6 | Minimum | 6 | 87 | 224-766 | 13.4-46 | 474-1623 | 250 | 335 | 75 | 7269 / 16025 |
| Effective | 7 | 102 | 223-743 | 13.4-44.6 | 472-1573 | |||||
| Maximum | 8.6 | 125 | 222-679 | 13.3-40.8 | 470-1440 | |||||
| ZT 315 VSD – 8.6 | Minimum | 6 | 87 | 311-907 | 18.7-54.4 | 659-1921 | 315 | 422 | 75 | 7484 / 16499 |
| Effective | 7 | 102 | 310-906 | 18.6-54.4 | 657-1920 | |||||
| Maximum | 8.6 | 125 | 309-840 | 18.6-50.4 | 656-1781 | |||||
| ZT 200 VSD – 10.4 | Minimum | 6 | 87 | 190-530 | 11.4-31.8 | 403-1122 | 200 | 268 | 72 | 7159 / 15783 |
| Effective | 9 | 131 | 188-525 | 11.3-31.5 | 398-1113 | |||||
| Maximum | 10.4 | 151 | 187-481 | 11.2-28.9 | 396-1020 | |||||
| ZT 250 VSD – 10.4 | Minimum | 6 | 87 | 194-698 | 11.6-41.9 | 410-1479 | 250 | 335 | 73 | 7269 / 16025 |
| Effective | 9 | 131 | 192-662 | 11.5-39.7 | 406-1402 | |||||
| Maximum | 10.4 | 151 | 191-616 | 11.4-37 | 404-1305 | |||||
| ZT 315 VSD – 10.4 | Minimum | 6 | 87 | 292-884 | 17.5-53 | 619-1873 | 315 | 422 | 74 | 7484 / 16499 |
| Effective | 9 | 131 | 290-828 | 17.4-49.7 | 615-1754 | |||||
| Maximum | 10.4 | 151 | 290-774 | 17.4-46.5 | 614-1641 | |||||
Dimensions ZT 160-315 (VSD) iMD
| Model | Length | Width | Height |
| mm/inches | |||
| ZT 160-315 (VSD) FF (iMD) | 4962 / 195.5 | 1760 / 69,3 | 2150 / 85 |
Specifications ZT 160-315 iMD
| Type | Frequency | Working pressure | Free Air Delivery | Installed motor power | Noise level | Weight (LV) | Weight (MV) | |||||
| (Hz) | bar(g) | psi(g) | l/s | m³/min | cfm | kW | hp | dB | kg/lbs | |||
| ZT 160 | ZT 160 7.5 | 50 | 7.5 | 109 | 498 | 29,9 | 1056 | 160 | 215 | 73 | 6817 / 12813 | 7678 / 14709 |
| ZT 160 8.6 | 50 | 8.6 | 125 | 459 | 27,5 | 973 | 73 | |||||
| ZT 160 8.6 | 60 | 8.6 | 125 | 451 | 27,1 | 957 | 72 | |||||
| ZT 160 10 | 50 | 10 | 145 | 407 | 24,4 | 864 | 73 | |||||
| ZT 160 10.4 | 60 | 10.4 | 151 | 400 | 24,0 | 849 | 75 | |||||
| ZT 200 | ZT 200 7.5 | 50 | 7.5 | 109 | 637 | 38,2 | 1350 | 200 | 268 | 77 | 6907 / 13012 | 7728 / 14819 |
| ZT 200 8.6 | 50 | 8.6 | 125 | 584 | 35,0 | 1237 | 73 | |||||
| ZT 200 8.6 | 60 | 8.6 | 125 | 579 | 34,8 | 1228 | 73 | |||||
| ZT 200 10 | 50 | 10 | 145 | 524 | 31,5 | 1112 | 72 | |||||
| ZT 200 10.4 | 60 | 10.4 | 151 | 498 | 29,9 | 1056 | 76 | |||||
| ZT 250 | ZT 250 7.5 | 50 | 7.5 | 109 | 786 | 47,2 | 1667 | 250 | 335 | 73 | 7117 / 13475 | 8058 / 15547 |
| ZT 250 8.6 | 50 | 8.6 | 125 | 741 | 44,4 | 1570 | 77 | |||||
| ZT 250 8.6 | 60 | 8.6 | 125 | 690 | 41,4 | 1463 | 74 | |||||
| ZT 250 10 | 50 | 10 | 145 | 687 | 41,2 | 1456 | 73 | |||||
| ZT 250 10.4 | 60 | 10.4 | 151 | 613 | 36,8 | 1298 | 76 | |||||
| ZT 275 | ZT 275 8.6 | 60 | 8.6 | 125 | 774 | 46,4 | 1640 | 275 | 369 | 77 | 7137 / 13519 | 8016 / 15454 |
| ZT 275 10.4 | 60 | 10.4 | 151 | 674 | 40,4 | 1428 | 74 | |||||
| ZT 300 | ZT 300 7.5 | 50 | 7.5 | 109 | 849 | 50,9 | 1799 | 300 | 400 | 75 | 7193 / 13519 | 8115 / 15547 |
| ZT 300 8.6 | 50 | 8.6 | 125 | 821 | 49,2 | 1740 | 75 | |||||
| ZT 300 8.6 | 60 | 8.6 | 125 | 841 | 50,4 | 1782 | 75 | |||||
| ZT 300 10 | 50 | 10 | 145 | 772 | 46,3 | 1637 | 76 | |||||
| ZT 300 10.4 | 60 | 10.4 | 151 | 771 | 46,3 | 1635 | 77 | |||||
| ZT 315 | ZT 315 7.5 | 50 | 7.5 | 109 | 928 | 55,7 | 1967 | 315 | 425 | 77 | 7193 / 13519 | 8115 / 15547 |
| ZT 315 8.6 | 50 | 8.6 | 125 | 872 | 52,3 | 1850 | 75 | |||||
| ZT 315 8.6 | 60 | 8.6 | 125 | 889 | 53,3 | 1884 | 77 | |||||
| ZT 315 10 | 50 | 10 | 145 | 820 | 49,2 | 1739 | 77 | |||||
| ZT 315 10.4 | 60 | 10.4 | 151 | 815 | 48,9 | 1728 | 77 | |||||
(1) Unit performance measured according to ISO 1217, Annex E, Edition 4 (2009).
Reference conditions:
– Relative humidity 0%
– Absolute inlet pressure 1 bar (14.5 psi)
– Intake air temperature 20°C (68°F)
Free Air Delivery (FAD) is measured at effective working pressure.
(2) A-weighted emission sound pressure level at the work station (LpWSAd). Measured according to ISO 2151:2008 using ISO 9614-2 (sound intensity scanning method). The added correction factor (+/- 3 db(A)) is the total uncertainty value (KpAd) conform with the test code.