Technical specifications Pack ZT
Specifications ZT 160-315 (VSD)
| Model | Working pressure | Free Air Delivery | Installed Power | Noise level | Weight | |||||
| bar(g) | psi(g) | l/s | m³/min | cfm | kW | hp | db(A) | kg /lbs | ||
| ZT 200 VSD- 8.6 | Minimum | 4 | 58 | 195-637 | 11.7-38.2 | 414-1350 | 200 | 268 | 75 | 6162 / 13585 |
| Effective | 7 | 102 | 193-608 | 11.6-36.5 | 410-1289 | |||||
| Maximum | 8.6 | 125 | 192-544 | 11.5-32.7 | 407-1153 | |||||
| ZT 250 VSD – 8.6 | Minimum | 4 | 58 | 225-767 | 13.5-46 | 477-1625 | 250 | 335 | 75 | 6272 / 13827 |
| Effective | 7 | 102 | 223-758 | 13.4-45.5 | 472-1605 | |||||
| Maximum | 8.6 | 125 | 222-688 | 13.3-41.3 | 470-1458 | |||||
| ZT 315 VSD – 8.6 | Minimum | 4 | 58 | 281-944 | 16.8-56.6 | 594-2000 | 315 | 422 | 75 | 6422 / 1418 |
| Effective | 7 | 102 | 279-926 | 16.7-55.6 | 591-1963 | |||||
| Maximum | 8.6 | 125 | 278-856 | 16.7-51.4 | 589-1814 | |||||
| ZT 200 VSD – 10.4 | Minimum | 6 | 87 | 190-530 | 11.4-31.8 | 404-1123 | 200 | 268 | 72 | 6162 / 13585 |
| Effective | 9 | 131 | 188-529 | 11.3-31.7 | 398-1120 | |||||
| Maximum | 10.4 | 151 | 187-482 | 11.2-28.9 | 396-1022 | |||||
| ZT 250 VSD – 10.4 | Minimum | 6 | 87 | 194-698 | 11.6-41.9 | 411-1479 | 250 | 335 | 73 | 6272 / 13827 |
| Effective | 9 | 131 | 192-672 | 11.5-40.3 | 406-1424 | |||||
| Maximum | 10.4 | 151 | 190-621 | 11.4-37.2 | 404-1315 | |||||
| ZT 315 VSD – 10.4 | Minimum | 6 | 87 | 263-885 | 15.8-53.1 | 556-1875 | 315 | 422 | 74 | 6422 / 1418 |
| Effective | 9 | 131 | 261-844 | 15.6-50.6 | 552-1787 | |||||
| Maximum | 10.4 | 151 | 260-786 | 15.6-47.1 | 550-1665 | |||||
Dimensions ZT 160-315 (VSD)
| Model | Length | Width | Height |
| mm / inches | |||
| ZT 160-315 (VSD) | 4438 / 175 | 1760 / 69.3 | 2150 / 85 |
Specifications ZT 160-315
| Type | Frequency | Working pressure | Free Air Delivery | Installed motor power | Noise level | Weight (LV) | Weight (MV) | |||||
| (Hz) | bar(g) | psi(g) | l/s | m³/min | cfm | kW | hp | dB | kg | |||
| ZT 160 | ZT 160 7.5 | 50 | 7.5 | 109 | 498 | 29,9 | 1056 | 160 | 215 | 73 | 5812 / 12813 | 6672 / 14709 |
| ZT 160 8.6 | 50 | 8.6 | 125 | 459 | 27,6 | 973 | 73 | |||||
| ZT 160 8.6 | 60 | 8.6 | 125 | 452 | 27,1 | 957 | 72 | |||||
| ZT 160 10 | 50 | 10 | 145 | 408 | 24,5 | 864 | 73 | |||||
| ZT 160 10.4 | 60 | 10.4 | 151 | 401 | 24,0 | 849 | 75 | |||||
| ZT 200 | ZT 200 7.5 | 50 | 7.5 | 109 | 637 | 38,2 | 1350 | 200 | 268 | 77 | 5902 / 13012 | 6722 / 14819 |
| ZT 200 8.6 | 50 | 8.6 | 125 | 584 | 35,0 | 1237 | 73 | |||||
| ZT 200 8.6 | 60 | 8.6 | 125 | 579 | 34,8 | 1228 | 73 | |||||
| ZT 200 10 | 50 | 10 | 145 | 525 | 31,5 | 1112 | 72 | |||||
| ZT 200 10.4 | 60 | 10.4 | 151 | 499 | 29,9 | 1056 | 76 | |||||
| ZT 250 | ZT 250 7.5 | 50 | 7.5 | 109 | 787 | 47,2 | 1667 | 250 | 335 | 73 | 6112 / 13475 | 7052 / 15547 |
| ZT 250 8.6 | 50 | 8.6 | 125 | 741 | 44,5 | 1570 | 77 | |||||
| ZT 250 8.6 | 60 | 8.6 | 125 | 690 | 41,4 | 1463 | 74 | |||||
| ZT 250 10 | 50 | 10 | 145 | 687 | 41,2 | 1456 | 73 | |||||
| ZT 250 10.4 | 60 | 10.4 | 151 | 613 | 36,8 | 1298 | 76 | |||||
| ZT 275 | ZT 275 8.6 | 60 | 8.6 | 125 | 774 | 46,4 | 1640 | 275 | 369 | 77 | 6132 / 13519 | 7010 / 15454 |
| ZT 275 10.4 | 60 | 10.4 | 151 | 674 | 40,4 | 1428 | 74 | |||||
| ZT 300 | ZT 300 7.5 | 50 | 7.5 | 109 | 849 | 50,9 | 1799 | 300 | 400 | 75 | 6132 / 13519 | 7052 / 15547 |
| ZT 300 8.6 | 50 | 8.6 | 125 | 821 | 49,3 | 1740 | 75 | |||||
| ZT 300 8.6 | 60 | 8.6 | 125 | 841 | 50,5 | 1782 | 75 | |||||
| ZT 300 10 | 50 | 10 | 145 | 772 | 46,3 | 1637 | 76 | |||||
| ZT 300 10.4 | 60 | 10.4 | 151 | 771 | 46,3 | 1635 | 77 | |||||
| ZT 315 | ZT 315 7.5 | 50 | 7.5 | 109 | 928 | 55,7 | 1967 | 315 | 425 | 77 | 6132 / 13519 | 7052 / 15547 |
| ZT 315 8.6 | 50 | 8.6 | 125 | 873 | 52,4 | 1850 | 75 | |||||
| ZT 315 8.6 | 60 | 8.6 | 125 | 889 | 53,4 | 1884 | 77 | |||||
| ZT 315 10 | 50 | 10 | 145 | 821 | 49,2 | 1739 | 77 | |||||
| ZT 315 10.4 | 60 | 10.4 | 151 | 815 | 48,9 | 1728 | 77 | |||||
(1) Unit performance measured according to ISO 1217, Annex E, Edition 4 (2009).
Reference conditions:
– Relative humidity 0%
– Absolute inlet pressure 1 bar (14.5 psi)
– Intake air temperature 20°C (68°F)
Free Air Delivery (FAD) is measured at effective working pressure.
(2) A-weighted emission sound pressure level at the work station (LpWSAd). Measured according to ISO 2151:2008 using ISO 9614-2 (sound intensity scanning method). The added correction factor (+/- 3 db(A)) is the total uncertainty value (KpAd) conform with the test code.